Company aimQuality first Favourable price Highest service All is for god Company slogan:Landa electric apparatus Pursue being outstanding Theory:Improved standard Knowledge talent Promise:Give me a chance,I will do better!  
  HomeCompanyGuide lookAchievementProductNew productTechnical equipmentOrderContact中文  
 

Now site>>>New product
 
<New product>
The high protection grade MNS switch cabinet installs the unit fixedly
HXGN□-12Z Small-scale vacuum openning circuit machine cupboard
    HXGN□-12Z type type case exchange metal finish sealing vacuum ring network cupboard and combine our country supply power development ask by type( regular). The equipment of electric apparatus of new-type high pressure that was jointly produced by our factory and Guangdong Zhu Jiang River switch Co., Ltd.. Performance reach IEC" exchange metal seal switchgear and control KVs exchange 3 - metal seal" and 3906 GB" equipment at 298. It has filled in the domestic blank, adopts the module to design, it is small to have volume, It operates frequently, long in time between overhauls(TBO) it is convenient for installation not to wait for characteristic, Reach the present international similar products level. (width 850mm×2000mm×1000mm)

    Suitable for the small-scale transformer substation three times, turn on and close specifieds voltage of three-phase, such as, wind power station, factories and mines, housing district, skyscraper, school, park,etc. 10 KVs, Among systems, as accepting and assign by electric energy with 50 frequencieses the distributions of the Hzses with,use in supply power at terminal stations for networks for ring .
Technical parameter:
Main technical parameter
Specified voltage(kV)
12
Amount holds up and turns on and break the electric current(kA)
31.5
Specified electric current(A)
1250
The meritorious load of amount is turned on and breaks the electric current (A)
/
Specified frequency(Hz)
50
It is turned on and broken that amount shifts the electric current(A)
/
4s amount tolerance electric current in short-term (kA)
31.5
Amount holds up and turns off and shut the electric current(peak value)(kA)
80
Specified peak value tolerance electric current(kA)
80
The different looks earth connection trouble is had and broken and tested (kA)
27.4
Amount Engineer is able to bear the voltage of receiving frequently in short-term(kV)
42
The number of times of the mechanical life-span(time)
10000
The specified thunder and lightning assault the voltage of tolerance (kV)
75
Amount operates the way
O0.3sCO
180sCO
The worker is able to bear the voltage of receiving frequently when fracture amount is short (kV)
48
/
/
The fracture specified thunder and lightning assault the voltage of tolerance( peak value )(kV)
85
/
/
>>>Back
 
 
 
copyright © 2003 landa electrical